Chapter 8: INSTALLATION AND SETTING PROCEDURES (HARDWARE)
2. VX-2000, VX-200XR, VX-200XI, AND EV-200
8-23
2.9.2. Setting the VX-2000's UK standby mode (switch 5)
[Switch 5 setting] ON: UK standby mode
OFF: Normal mode
When power fails, the VX-2000 turns into the UK standby mode, permitting general broadcast from both the
RM-200XF and the Emergency type RM-200X.
Attention
The standby mode is provided for emergency activation in power failure. To ensure operation in the UK standby
mode, prepare sufficient battery capacity or pay attention to make announcements from emergency type
remote microphones as briefly as possible in order to prevent excessive battery consumption.
Notes
• Thisfunctionappliestotheversion2.10orlaterfirmware(VX-2000andVX-2000SF).
• TheVX-2000SFrequiresnosetting.
• Theselectedmode(UKstandbyornormal)ismadevalidaftertheVX-2000isreset.
[DIP switch settings]
Note: Leave all switches except 5 OFF.
2.8. Mounting the VX-200XR and VX-200XI in the VX-2000 System Manager
Notes
• The slot number and module type to be installed must be identical to those designated by the PC software.
• Cover idle slots with the supplied blank panels to prevent dust from getting into the equipment.
Blank panel
(supplied with the VX-2000)
Mounting screw
(supplied with the VX-2000)
VX-2000
VX-200XR
Slot 1
Slot 8
Mounting screw (supplied with the VX-200XR)
Setting DIP switch
SETTINGS
[VX-2000 Front panel detached]
2.9. VX-2000 System Manager's DIP Switch Settings
2.9.1. DIP switch functions
Switch No. 1 2 3 4 5 6 7 8
Function Unused UK standby mode ON/OFF Unused