Safe Inter. Temp.: Above this temperature value, the
device will stop the main port output
Safe Exter. Temp.: If the external sensor detects a
temperature higher than this value, the device will stop
the main port output
Safe time: The maximum time of continuous charging
and discharging will stop working if exceeded
Safe capacity: The maximum capacity of continuous
charging and discharging will stop working if exceeded
Continuous work: After charge and discharge, whether
to continue charge and discharge after battery
replacement
Work completed: Whether to stop or trickle charge after
charge done
Battery selection: Option to open and close the battery