MINTER Description and Configuration
P/N 7010-0935
3-13
Files (total) – a counter that specifies how many multiple log files
must be created in AFRM until this mode automatically turns off.
This counter decrements on every file rotation until its value
becomes zero, then file rotation automatically stops. The counter
initializes with AFRM.
Note that a log file opens immediately after turning AFRM on.
This startup file is not considered a file rotation event; the AFRM
counter will not decrement.
Values are 0 to [2
31
-1]; default value is 0 (zero). Zero means that
an unlimited number of log files will be created.
Files (remain) – specifies the number of files left for the receiver
to create in AFRM. Values are 0 to [2
31
-1]; default value is zero.
Automatically remove old files – when no free memory is
available to log data, automatically removes the earliest log file. If
this parameter is enabled, your receiver will erase the file with the
earliest file creation time/date. AFRM must be enabled to use this
FIFO (First-In, First-Out) feature. The default value is off
(disabled).
FN Key Mode parameter Use these two radio buttons to program
how the receiver will react when pressing the FN key.
LED blink mode switch – pressing FN will toggle between the
MINTER’s normal/extended information modes and start/stop
data recording of Static survey.
FN pressed for less than 1 second: changes the information
mode (Normal or Extended Information Modes).
FN pressed for 1 to 5 seconds: starts or stops data recording
(Static post-processing mode).
Occupation mode switch – pressing FN (less than one second)
will insert into the corresponding log file a message indicating
that the survey type has been changed from static to kinematic, or
vice versa. If the REC LED blinks green, the current mode is
NOTICE
The receiver’s memory holds up to 1024 files.
Net-G3A_OM_Book.book Page 13 Thursday, May 14, 2009 8:49 AM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon Net-G3 and is the answer not in the manual?

Topcon Net-G3 Specifications

General IconGeneral
BrandTopcon
ModelNet-G3
CategoryReceiver
LanguageEnglish

Related product manuals