35
5) Safety Lock System
When the instrument system detects a shock, this function informs the operate of it. (A safety
lock is also called a height alert.)
In case the safety lock system setting is ON, Safety Lock System will active. (This will be active
around 10 minutes after turning on the power.)
Should the installed status of the instrument suddenly change when auto-leveling is functioning
and laser beam is being emitted, through, for example, unnecessary contact by the user, the
auto-leveling function will automatically stop to protect operational precision.
In such a case, the rotary head will act as below:
When [6) Warning transmission] is activated: it will rotate slowly
When [6) Warning transmission] in not activated: the rotation will stop
How to reactivate
Turning off the power for the instrument, and then turning it back on will activate the auto-leveling
function.