Do you have a question about the Topcon RL-100 2S and is the answer not in the manual?
Type | Rotary Laser Level |
---|---|
Self-Leveling | Yes |
Laser Wavelength | 635 nm |
Laser Class | Class 2 |
Waterproof/Dustproof | Yes |
IP Rating | IP66 |
Accuracy | ±1.5mm at 30m |
Operating Range | 800 m (diameter) with laser receiver |
Self-Leveling Range | ±5 degrees |
Rotation Speed | 600 RPM |
Power Source | Rechargeable battery |
Covers risks of fire, electric shock, physical harm, and eye injury from improper use or disassembly.
Compliance with regulations and warnings regarding laser beam exposure and servicing.
Instructions for setting up the instrument on a tripod within ±5 degrees of level.
Steps to establish a target line parallel to the desired direction of grade.
Instructions for positioning the laser, rough alignment, and sighting with the collimator.
Initiating grade input by pressing the X/Y key.
Using arrow keys to select grade type and adjust numerical values.
Finalizing grade input by pressing the Enter key.
Procedure to set up masking (shutting off laser beam) and change shut-off directions.
Instructions on how to set the rotary head speed to 300, 600, or 900 R.P.M.
Procedure for searching and setting channels on the RC-400.
Explanation of selecting sensitivity level for vibration tolerance during operation.
Details on how the Safety Lock System activates to protect precision during operation.
Step-by-step guide for replacing dry batteries in the main instrument.
Information on installing and charging rechargeable batteries.
Procedure for checking and calibrating the horizontal alignment of the instrument.
Detailed steps to check the initial calibration of the instrument.
How to use arrow keys to adjust the laser beam position for calibration.
Setup for checking horizontal rotation cone error by using two walls.
Measuring the differences in laser beam positions to detect errors.
Procedure to check for grade setting errors after horizontal calibration and cone error checks.
Setup for checking grade setting errors with a staff.
Setting the Y axis grade to 1.00% for error checking.
Using elevation readings to calculate and verify the grade setting accuracy.
Technical specifications for the RL-100 2S rotating laser.
Technical specifications for the RC-400 remote controller.
Error code and description for low battery on the RL-100 and RC-400.