5) Safety Lock System (Height Alert)
In case the [ALERT] setting is ON. Safety Lock System will active. (This will be active around
10 minutes after turning on the power.)
Should the installed status of the instrument suddenly change when automatic alignment is
functioning and laser beam is being emitted, through, for example, unnecessary contact by the
user, the automatic alignment function will automatically stop to protect operational precision.
In such a case, the rotary head will act as below:
When [6) Warning transmission] is activated: it will rotate slowly
When [6) Warning transmission] in not activated: the rotation will stop
How to reactivate
Turning off the power for the instrument, and then turning it back on will activate the automatic
alignment function.
Active
Inactive
Error : Blinks alternately