DL-501
INSTRUCTION MANUAL
DIGITAL LEVEL
21122 99024
DL-501_E.book -i ージ 015年9月17日 木曜日 午後1時21分

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Topcon DL-501 and is the answer not in the manual?

Topcon DL-501 Specifications

General IconGeneral
Operating Temperature-10°C to +50°C
RangeUp to 100m with detector
Working RangeUp to 100m with detector
Leveling Time3 seconds
Laser Diode635nm, Class 2 laser
Battery Type4 x AA batteries

Summary

1. PRECAUTIONS FOR SAFE OPERATION

4. BASIC OPERATION

4.1 Basic Key Operation

Details on powering the instrument on/off and basic button functions.

5. USING THE BATTERY

5.1 Battery Charging

Procedure for charging the instrument's battery using the provided charger.

5.2 Installing/Removing the Battery

Instructions for safely installing and removing the battery from the instrument.

6. SETTING UP THE INSTRUMENT

6.1 Setting Up

Steps for properly mounting and securing the instrument onto a tripod.

6.2 Leveling

Methods for leveling the instrument using circular bubble or screen display.

7. POWER ON/OFF

8. FOCUSING AND SIGHTING THE STAFF

9. CONNECTING TO EXTERNAL DEVICES

10. BASIC OPERATION

11. SIMPLE MEASUREMENT

11.1 Measuring Height Difference

Calculating height difference between two points without setting a route.

11.2 Measuring Elevation

Calculating elevation of a point based on a known point's elevation.

12. HEIGHT DIFFERENCE MEASUREMENT

12.1 Route Setup

Setting up a route by selecting an existing route or creating a new one.

12.2 Height Difference Measurement

Measuring height difference along a set route using backsight/foresight sequences.

12.3 Setting-Out Measurement

Finding a point at a specified elevation, relative height, or distance.

14. CALCULATION FUNCTIONS

14.1 Double-run Discrepancy

Calculates and displays discrepancies between go and return runs for leveling.

14.2 Closure Error

Calculates closure errors for leveling links and loops.

14.3 Adjusting for Closure

Methods for distributing closure error among points on a route.

15. SELECTING/DELETING A JOB

16. ROUTE SETTINGS

17. MANAGING KNOWN POINT DATA

18. OUTPUTTING DATA

18.1 Outputting JOB Data

Steps to output JOB data to a host computer or external memory device.

18.2 Outputting Route Data

Procedures for outputting route data to host computer, SD card, or USB memory.

19. CHANGING THE SETTINGS

21. CHECKS AND ADJUSTMENTS

21.1 Circular Level

Checking and adjusting the circular level for proper instrument leveling.

21.2 Tilt Sensor

Procedure to cancel tilt zero point errors and calibrate the tilt sensor.

21.3 Adjusting the Reticle

Correcting the reticle cross-lines for accurate measurements.

Related product manuals