71
Error Indication
RC-30 Remote control Using with RL-VH3G/A/B
Operating distance : Max. 90m (295ft)
(Operating distance will vary depending on environmental condi-
tions.)
LEDs 123456789
10
Countermeasures
Tilt system error B B B BBBBBBB
Turn OFF and ON again.
Vertical beam align-
ment range err.
A
Setup the instrument and try to
align the beam again.
Slope setting range
err. (X or Y axis)
A
Y err.
A
X err.
Setup the instrument again and try
to set slope again.
Auto-leveling range
over
13 2
Setup the instrument again.
Height alert B B B
Turn OFF and ON again.
Internal memory err. B
Turn OFF and ON again.
Mechanical err. Laser beam blinks.
Turn OFF and ON again.
If errors still persist after attempting to clear them, contact your dealer or Topcon.
1
2
3
4
5
6
7
8
9
10
B: Blink
A: Alternate blink
Number: Blinks in order