EasyManua.ls Logo

Topkodas PROGATE - Page 43

Topkodas PROGATE
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROGATE User manual V-2022-09-20 43 | EN
INST000000˽071˽N#VALUE #
Programming of minimal sensors value upon reaching the SMS message with „Low Alarm“
text will be sent
071= command code (min sensors value upon reaching which, the SMS message with „Low Alarm“
text will be sent)
N = sensor number
VALUE = Format 0000.00 Low Alarm Value
INST000000˽072˽N#VALUE#
Programming of sensor max value upon reaching the selected output will be activated. For
example cooling equipment
072= command code (sensor max value upon reaching the selected output will be activated.)
N = sensor number
VALUE= Format 0000.00 sensor max value upon reaching, the selected output will be activated.
INST000000˽073˽N#VALUE#
Programming of sensor min value upon reaching the selected output will be activated. For
example heating equipment
073= command code (sensor min value upon reaching the selected output will be activated.)
N = sensor number
VALUE= Format 0000.00 Sensor min value upon reaching which, the output will be activated.
INST000000˽090˽NewInstPsw
Change installers password (Installers password should be changed before exploitation of the
module)
090= command code (Change of installer‘s password)
NewInstPsw = New Installer‘s password.
INST000000˽091˽NewUserPsw
e.g.
INST000000˽091˽654321
Change user‘s password (User‘s password should be changed before exploitation of the module)
091= command code (Change user‘s password)
NewUserPsw = New user‘s password.
INST000000˽092
Remote reset of the module via SMS messages
092= command code (Remote reset of the module via SMS messages )
INST000000˽093˽yyyy/MM/dd#HH:mm#
Time of the module setting via SMS message.
The time is usually synchronized via a server or mobile network. However, if synchronization is disabled, it can be set manually via
SMS.
093= command code (Time of the module setting via SMS message)
Time format of the module:
yyyy/MM/dd#HH:mm#
yyyy -year
MM-month 1-12
dd - day of the month 1-31
HH-hours 0-23
mm- minutes 0-59
INST000000˽094˽TEL#SMS
e.g.
INST000000˽094˽+370616111111#Hello
SMS from the module forwarding to the other phone number
094= command code (SMS from the module resending to the other phone number)
TEL = phone number to which will be forwarded sms text
SMS = sms text that will be send to the referred number.
TEL=861611111111 local number or international format e.g. +370616111111
SMS text =Latin Charset
After this commands could not be other commands like: 094 SMS 030 1
because all messages will be forwarded to other numer "SMS 030 1"
INST 000000˽095˽E
Zone Walk Test request
095= command code (Zone Test request)
E = 1- test request activated, 0- test request deactivated
When zone is activated, the bell generates the sound,
ARM/DISARM system automatically turn off this function
INST 000000˽096
Fire sensors reset.
INST000000˽100˽N
System state request:
100= command code (System state request)
N = System state request type
1- System test request, Request information about the module (: IMEI, FW, LEVEL etc.)
2- the values of active sensors request
3 -Request about active zone states
4 -Request about output states
5 - System state request. The module will send information on input/output states and system state
(ARM/DISARM/STAY).