10 Instructions for Use TORMAX 2101 T-1672 e
Operation in the Event of a Power Failure
Depending on the equipment installed, the following functions are possible:
With 6 V Battery Module u
In operating mode AUTO: The door opens immediately and remains open.
In operating mode OFF: The door remains closed if it was locked mechanically at the moment of
power failure. Otherwise the door opens and remains open.
When power is restored the door closes again and functions according to the set operating mode.
With Battery Unit u
Continued operation of the system by means of a battery unit u for a specific time with the doors
opening before the battery switches off. The door remains locked in operating mode OFF.
Unlocking and opening of the door from outside by means of a key switch and the battery unit u.
When power is restored the door closes again and functions according to the set operating mode.
Without 6 V Battery Module u / Battery Unit u
In operating mode AUTO or OPEN: The door stands still and is then freely movable.
In operating mode OFF: The door remains locked if a lock is installed. Otherwise the door leaves
are freely movable.
When power is restored the door closes again and functions according to the set operating mode.
3.3 Operating Modes
Operating Mode OFF
The internal and external sensors are disregarded. The door is maintained in the closed position by
the motor and/or locked by the electro-mechanical lock u. Access is only possible using the key
switch u. The door can still be used for 10 seconds after selecting operating mode OFF from inside to
out.
Operating Mode AUTO
The operating mode AUTO is normally used during the day. The door opens automatically to its full
opening width to both sides by means of the internal and external sensors.
Operating Mode AUTORED
Operating mode AUTORED (Automatic Reduced) is normally used during the day. The door opens
automatically (normally with a reduced opening width) to both sides by means of the internal and ex-
ternal sensors.
< If required, the opening width and hold open time can be adjusted by the installer.
Operating Mode EXIT
Operating mode EXIT is normally used for the period before the shop or office closes. The door will
only open automatically when activated by the internal sensor.
When the door opens the external sensor is also monitored for safety reasons.