18 Instructions for Use iMotion 1301.FIRE /1401.FIRE T-1540 e
7.3 Functional Check of the Swing Door System
The operator must check the function and safety devices of the automatic swing door at least
every three months. This will ensure that faults or hazardous changes in the system are detected
at an early stage. See section 8.2 “Check-list for Functional Checks” for items to be checked.
You should arrange for any defects detected during the routine checks to be rectified immediately by
a TORMAX dealer (see the last page of this manual for the address).
Warning
Potential switching malfunction in the automatic swing door.
Potential hazards – injury caused by impact or crushing.
• Secure the area around the door while checking the door's functions.
7.4 Maintenance and Testing
Maintenance and testing should only be carried out by a trained skilled person following the manufac-
turer’s instructions.
Warning
Possible risk of injury!
Entrapment of limbs can lead to serious injury.
• The drive must be disconnected from all power sources, including batteries during main-
tenance and replacement of parts.
Maintenance Interval
The operator is obliged to have the hold-open system checked at least once a year for proper and
trouble-free interaction of all devices and to have it serviced.
Scope of the Maintenance Work
The content of the maintenance work is specified by the manufacturer in an inspection list.
System Test Book
The test findings are recorded after the test in the system test book. The operator must keep it in a safe
place.