10 Instructions for Use iMotion 1301/1301.S /1401 T-1305 e
4.3 Operation with an Operating Mode Switch u
Selection of Operating Modes
The switch position defines the operating mode.
T1305_4
OFF
AUTOMATIC 1
OPEN
Resetting the system
– Changetheoperatingmodeintheeventof afault
or
– Cutoffpowersupplytothesystemforatleast5seconds.
4.4 Operation on Power Failure
Opening a Door using a Key Switch u with a Battery Unit u
• Turnthekeyswitchtothe“on”positionandholdinplaceforatleast5seconds,thenturnthekeyto
the original position.
The battery is activated using the “wake up” function.
The key switch must not remain permanently in the “on” opposition.
The door is unlocked and opened.
The battery switches off again after the time programmed
< by the installation engineer or
when the battery is fully discharged.
If required, the operating mode can be changed on the user interface during the wake-up.
4.5 Resetting the Panic Fitting u
• SelectoperatingmodeOFF(operatingmodeswitch, user interface )ordisconnecttheoperator
frommains(installationswitch,mainsplug).
• Pushthedoorleafbackintotheinitialposition.
• ChooseoperatingmodeAUTOMATIC1orswitchonoperator.