Instructions for Use iMotion 1301/1301.S /1401 T-1305 e 5
Hazards can arise:
– intheregionofallclosingedges(particularlyclosetothehinge)
– intheregionofthelinkagelever
– if,forexample,salesstandsareerectedindirectproximitytotheoperatingrangeofthedoorleaves
– duetodeliberatedamagebyvandals,defectivesensorsorsensorswhicharenolongerproperlyad-
justed, sharp edges, incorrectly supported and defective casing or missing covers.
2.5 Checks
TheregularchecksandexaminationssetoutinChapter6mustbecarriedoutasinstructedbythemanu-
facturer. The manufacturer recommends that a maintenance contract be concluded in order to operate the
system safely and to maintain its value for as long as possible.
2.6 Decommissioning the System in the Event of a Fault
If there is a fault the automatic swing door may only be taken out of service by a skilled person, the op-
erator or a person who is instructed to do so by the operator. This must be done on all occasions on which
the safety of persons could be compromised.
• Disconnectthesystemfromthepowersupply.
• Selectoperatingmode“P”ifthesystemcontinuestooperateusingtheinternalemergencypowersup-
ply(seesection3.3foroperatingmodes).
• Openthedoormanuallyandsecureintheopenpositionifitisinstalledinanescaperoute.
• Firedoorsmustneverbesecuredintheopenpositioneveninemergencies.
See section 7 for rectification of faults.
2.7 Disposal
This system must be properly dismantled at the end of its working life. Its disposal must comply with na-
tional regulations. We recommend that you contact a skilled person disposal company.
– Aggressiveacids.
– Riskofinjuryif youdismantlethebatterymodule.
– Disposeofbatteriesproperly.
– Flyingaroundparts.
– Thetensionedspringrepresentsa
hazard when dismantling the drive.
– Beforeopeningthecasing,release
the tension on the spring up to the
stop as indicated in the drawing
(iMotion1301/1301.S:W=0)
– Brokenglass.
– Riskofinjurywhendismantlingthedoorleaves.
– Takecarewhentransportingthedoorleaves.
T1305_2
T1305_1
W
W