EasyManuals Logo

Tornado Floorkeeper 99328 User Manual

Tornado Floorkeeper 99328
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
21
TORNADO LONG-RANGE FLOORKEEPER®
TROUBLESHOOTING INSTRUCTIONS
This section is designed to instruct your personnel in methods of troubleshooting on the
Tornado Long-Range Floorkeeper.
Vacuum System (Poor Suction)
During machine operation, if the vacuum motor is running but the solution is not being picked
up, do the following:
Check for:
1. Full recovery tank. When tank is full, liquid shutoff closes to prevent water from entering
vacuum motor.
2. Loose hose on float/filter, creating an air leak.
3. Clogged filter.
4. Clogged stand pipe near filter. Remove cap to inspect and clean with hose.
5. A. Check to see that ball closure is in place on end of drain hose.
B. Check to see that thumb nuts on recovery tank drain cover are tight.
C. Check to see if liquid shutoff unit is properly seated on top of recovery tank, the filter
gasket is not damaged, and cam lock nuts are tight.
https://harrissupplyind.com - To Order Parts Call 608-268-8080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tornado Floorkeeper 99328 and is the answer not in the manual?

Tornado Floorkeeper 99328 Specifications

General IconGeneral
BrandTornado
ModelFloorkeeper 99328
CategoryScrubber
LanguageEnglish

Related product manuals