BeltMaintenance
Checktheconditionandtensionofthealternatorbelt
aftertherstdayofoperationandevery100operating
hoursthereafter.
TensioningtheAlternator
Belt
ServiceInterval:Aftertherst8hours—Check
theconditionandtensionofthe
alternatorbelt.
Every100hours
1.Openthehood.
2.Checkthetensionofthealternatorbeltby
pressingit(Figure63)midwaybetweenthe
alternatorandthecrankshaftpulleyswith10kg
(22lb)offorce.
g003976
Figure63
1.Brace3.Pivotbolt
2.Alternatorbelt
Note:Thebeltshoulddeect11mm(7/16
inch).Ifthedeectionisincorrect,proceedto
step3.Ifcorrect,continueoperation.
3.Loosentheboltsecuringthebracetotheengine
(Figure63),theboltsecuringthealternatorto
thebraceandthepivotbolt.
4.Insertaprybarbetweenthealternatorandthe
engineandpryoutonthealternator.
5.Whenyouachievethepropertension,tighten
thealternator,brace,andpivotboltstosecure
theadjustment.
HydraulicSystem
Maintenance
HydraulicSystemSafety
Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.