ReplacingtheFuelFilter
ServiceInterval:Every500hours
1.Closethefuelshutoffvalve(Figure35)below
thefueltank.
g008434
Figure35
1.Fuelshut-offvalve
2.Cleantheareawheretheltercanistermounts.
3.Placeadrainpanunderthefuellter.
4.Openthelterdrainplugandbreathervalve
(Figure36).
g254461
Figure36
1.Breathervalve3.Filterdrainplug
2.Fuellter
5.Removetheltercanisterandcleanthe
mountingsurface.
6.Lubricatethegasketontheltercanisterwith
cleanoil.
7.Installtheltercanisterbyhanduntilthegasket
contactsthemountingsurface,thenrotatean
additional1/2turn.
8.Tightenthedrainplugonthebottomofthelter
canisterandopenthefuelshutoffvalve.
9.Disposeofthefuelandlteraccordingtolocal
regulations.
InspectingtheFuelLines
andConnections
ServiceInterval:Every2years
Inspectthefuellinesfordeterioration,damage,or
looseconnections.