Figure 56
1. Test port B (Counter
balance)
2. Test port C ( Four wheel
drive)
T est P or t D ( Figure 57 ), located on front of pump
assembly , under operators seat plate . Used to measure
steering pressure .
T est P or t E ( Figure 57 ), located on front of pump
assembly , under operators seat plate . Used to measure
lift circuit pressure .
Figure 57
1. Test port D (Steering) 2. Test port E (Lift circuit)
T est P or t F ( Figure 58 ), located on top of right hand
dec k manifold. Used to measure cutting unit circuit
pressure for cutting units 5, 2 and 3.
T est P or t G ( Figure 58 ), located on top of left hand
dec k manifold. Used to measure cutting unit circuit
pressure for cutting units 1 and 4.
Figure 58
1. Test port F (Decks) 2. Test port G (Decks)
T est P or t H ( Figure 59 ) located on rear traction circuit
hard line . Used to measure rev erse traction pressure .
T est P or t I ( Figure 59 ) located on front traction circuit
hard line . Used to measure forw ard traction pressure
Figure 59
1. Test port H (Reverse) 2. Test port I (Forward)
Adjusting the
Counterbalance
T he counterbalance dial ( Figure 60 ) is used to
adjust the pressure in the counterbalance circuit.
R ecommended counterbalance pressure is 620 psi.
R otate the adjusting dial ( Figure 60 ) cloc kwise to
increase the pressure or countercloc kwise to decrease
the pressure .