HYDRAULICS & ENGINE MOUNTING
4-6
Toro 30” Aerator Service Manual
4
Fig. 072 aux hydraulic lter
Changing Auxiliary Hydraulic
Reservoir Fluid and Filter
Service Interval: After the rst 100 hours, every 250
hours thereafter
1. Stop engine, wait for all moving parts to stop.
Remove key and spark plug wires. Engage parking
brake.
2. Carefully clean area around the front of the auxiliary
pump and ll cap, and around the lter (Fig. 072).
Note: It is important that no dirt or contamination
enter hydraulic system.
3. Unscrew the suction hose from the pump tting,
clean around the pump tting and allow oil to drain
(Fig. 073).
Fig. 073 aux lter 2
4. Unscrew the lter to remove and allow oil to drain.
5. Apply a thin coat of Toro Hydro Oil
to the surface of
the rubber seal on the new oil lter. Turn the lter
clockwise until the rubber seal contacts the lter
adapter, then tighten the lter an additional 2/3 to 3/4
turn.
6. Reinstall the hose and torque (Fig. 074).
Fig. 074 aux lter 2
A. Torque to 37 ft.-lbs. (50 Nm)
7. Add Toro Hydro Oil until the level reaches the cold ll
line located on the reservoir tank. Start engine and
raise and lower the tines 3-4 times. Lower the tines
to the ground and rell the reservoir to the cold ll
line.
Note: Hydraulic oil ll level to be between “COLD”
bafe and down a 1/4” below. Check with the
aerator tines down (resting on the ground)
and uid temperature at 71
o
+ 10
o
F (21.6 +
6.6
o
C).
A