NewSPEEDCalnumber=148x500/Distance
readout
10.EnterthenewSpeedCalnumberusingtheprevious
procedure.
EnteringtheMeterCalNumber
UsethegalloncalibrationnumberforU.S.gallonsper
acreorU.S.gallonsper1000sq.ft.oralitercalibration
numberforlitersperhectare.
1.Pressthe[MeterCal]key.
2.Pressthe[Enter]key.
3.EntertheMeterCalcalibrationnumber.
Note:TheMeterCal(orowmeter)calibration
numberisstampedonthetagattachedtothe
owmeterormetercable.
4.Pressthe[Enter]key.
EnteringtheValveCalNumber
TheValveCalnumbercontrolstheresponseofthe
hydrauliccontrolvalvetochangethevehiclespeed.
Thisnumberconsistsofthreedigits:thevalvespeed
digit,thebrakepointdigitpercent,andthedead=band
digit.Forexample,fortheValveCalnumberof023,
thevalvespeeddigitis0,thebrakepointdigitpercent
is2,andthedead=banddigitis3.
Valvespeeddigit
Thisdigitcontrolstheresponsetimeofthecontrol
valvemotor.
Important:Runningthecontrolvalvetoofast(a
numbergreaterthanzero)willcausethesystem
tooscillate.
Range:0(slow)to9(fast)
Brakepointdigitpercent
Thisdigitsetsthepointatwhichthecontrolvalve
motorbeginstobraketopreventthesystemfrom
overshootingtheapplicationrate.Thedigitisthe
percentawayfromthetargetrate.
Range:0(0%)to9(90%);eachvaluerepresentsa
multipleof10%
Dead=Banddigit
Range:0(0%)to9(9%)
Thisdigitisthedifferencebetweenthetargetandthe
actualapplicationrate,wheretheratecorrectionisnot
performed.
ToentertheValveCalnumber:
1.Pressthe[ValveCal]key.
2.Pressthe[Enter]key.
3.EntertheValveCalcalibrationnumber.
Note:Theinitialvalvecalibrationnumberfor
ValveCalis023.Werecommendthatyouusethis
numberformostsprayapplications;063maybe
helpfulforsmallapplicationrates.
4.Pressthe[Enter]key.
EnteringRate1andRate2Data
Enterthesprayapplicationrate(withdecimal)inRate1
andRate2.EntertheratesinU.S.gallonsperacre(US
mode),U.S.gallonsper1,000squarefeet(TUmode),
orlitersperhectare(SImode)dependingonthebase
measurementyouselect.
1.Pressthe[Rate1Cal]key.
2.Pressthe[Enter]key.
3.Enterthetargetapplicationrate(ingal.peracre,
litersperhectare,orU.S.gallonsper1,000sq.feet)
thatyouwanttospray.
4.Pressthe[Enter]key.
5.Pressthe[Rate2Cal]key.
6.Pressthe[Enter]key.
7.Enterasecondtargetapplicationrate(inU.S.
gallonsperacre,litersperhectare,orU.S.gallonsper
1,000sq.ft.)thatyouwanttospray,ifyoudesire.
Note:Rate2shouldnotdiffermorethan20%
fromRate1.Ifyoudonotuseasecondrate,enter
thesamerateforRate1andRate2.
8.Pressthe[Enter]key.
Note:Youhavenowcompletedprogramming
theconsolecomputer.TheashingCALinthe
displayshouldstop.Ifnot,repeattheproceduresfor
programmingtheconsolecomputer.
EnteringOptionalCalibrationValues
Youmayalsowanttoenterthefollowingdata,butitis
notrequiredforoperatingthespraysystem.
VolumeTank
Thisnumberrepresentsthevolumeofmaterialinthe
tankandmustbeenteredeachtimeyourellthetank.
Thefunctionmonitorsthetankvolumewhileyouare
sprayingbasedonthetotalamountapplied.
1.Pressthe[Vol/Tank]key.
2.Pressthe[Enter]key.
3.Entertheamountofmaterialinthetank.
4.Pressthe[Enter]key.
Time
13