Note:Ifyoumakeadataentryerror,resetthe
consolecomputerbyturningthepowerswitchto
theOffpositionand,whilepressingandholding
the[CE]key,turningthepowerswitchtotheOn
position.
SelectingSP3
1.Pressthe[CE]keyuntilyouseeSP3.
Note:SP1isforwheeldriveandSP2isforradar
speeddriveandarenotused.Foryourconsole
computer,theSP3(geartoothdrive)istheproper
setting.
2.Pressthe[Enter]key.
Note:Thedisplayshows0intherighthand
window .Lefthandwindowwillstillbeshowing
CALuntilbuttons1-8havedataentered.
3.Toprogramthecomputerconsole,referto
ProgrammingtheConsoleComputer.
Note:Allthedataisretainedwhenyouturnthepower
switchtotheOffposition.
ProgrammingtheConsole
Computer
Important:Ensurethattheboombypassvalves
areclosed.
Movethepowerswitchontheconsolecomputerto
theOnposition.
Note:TurningthepowerswitchtotheOffposition
ordisconnectingtheconsolecablesdoesnoterasethe
datastoredintheconsolecomputermemory.
Important:Thecalibrationguresgivenare
guidelinesonly;youshouldperformcalculations
foryourparticularmachineandspraying
applicationsituationandconditions.
Note:Referto
Figure13andtheKeypadReference
Tableforthedescriptionandfunctionofthekeyson
theconsolecomputer.
CalculatingtheBoomCalData
CalculatetheBoomCalbymultiplyingthenumberof
spraytipsbythetipspacing.
Note:Boom1istheleftboom(fromtheoperating
position),Boom2isthecenterboom,andBoom3is
therightboom.
1.Pressthe[Boom1Cal]key.
2.Pressthe[Enter]key.
3.Enter80.
4.Pressthe[Enter]key.
5.Pressthe[Boom2Cal]key.
6.Pressthe[Enter]key.
7.Enter60.
8.Pressthe[Enter]key.
9.Pressthe[Boom3Cal]key.
10.Pressthe[Enter]key.
11.Enter80.
12.Pressthe[Enter]key.
EnteringtheSPEEDCalNumber
TheSPEEDCalnumberiscriticaltotheperformance
ofthespraysystem.Ensurethatthetiresareproperly
inatedandthatthetankishalffullbeforeperforming
thisprocedure.
1.Pressthe[SPEEDCal]key.
2.Pressthe[Enter]key.
3.EntercorrectSPEEDCalnumberforyourcurrent
selectedunitofmeasurment(US,SI,TU).
•WhenusingUSunitsenter:148.
•WhenusingSIunitsenter:38.
•WhenusingTUunitsenter:148
4.Pressthe[Enter]key.
Note:Thesenumbersallowthemachinetooperate
withreasonableaccuracy.Finetuningisnecessaryfor
maximumaccuracy.
Thefollowingprocedurerequiresbuttons1-8tohave
beenpopulatedwithdataandCALtostopashing.
Usethefollowingproceduretofurthernetunethe
SPEEDCalnumber
1.Measure500feetonaatgroundsurface.
2.Setthedistancereadoutto0.
3.Pressthe[Distance]key.
4.Pressthe[Enter]key.
5.Enter0.
6.Pressthe[Enter]key.
7.Drivethevehicle500feet.
8.Ensurethatthedistancereadoutontheconsole
computerreadsbetween490and510feet.
9.Ifthereadoutisnotbetween490
and510feet,calibratetheSPEED
Calusingthefollowingequation:
12