CorrectedMeterCal=(MeterCalxTotalVolume)/
AmountofWater
CorrectedMeterCal=(1660x103)/100
CorrectedMeterCal=1710.
Note:Repeatthisprocedureseveraltimestoconrm
thatthecorrectedMeterCalnumberisaccurate.
TestingtheFlowmeterCable
1.Disconnecttheconsolecontrolcablefromthe
owmetercable.
2.Holdthecablesothatthekeywayisinthe12o’
clockposition(Figure15).
Figure15
1.Keyway
3.Signal(6o’clockposition)
2.Ground(2o’clockposition)4.Power(10o’clockposition)
3.EnteraMeterCalnumber.RefertoEnteringthe
MeterCalNumberonpage8.
4.Pressthe[TotalVolume]key.
5.TurnthePump,Foot,andBoomswitchestotheOn
position.
6.Useasmalljumperwireorapapercliptocreatea
shortbetweenthe2o’clockand6o’clocksockets.
Note:Eachtimeyoumakecontact,theTotal
Volumeshouldincreaseby1ormorecounts.
7.IftheTotalVolumenumberdoesnotincrease,
replacethedefectivecable.
8.Performthevoltagechecks:2o’clockto6o’clock
(+5VDC);and2o’clockto10o’clock(+5VDC).
9.Ifallthecablesaregood,replacetheowsensor.
Note:Aftertestingtheowmetercables,enterthe
correctMeterCalnumberbeforespraying.