Toro 41086 - Testing the Flowmeter Cable

Toro 41086
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CorrectedMeterCal=(MeterCalxTotalVolume)/
AmountofWater
CorrectedMeterCal=(1660x103)/100
CorrectedMeterCal=1710.
Note:Repeatthisprocedureseveraltimestoconrm
thatthecorrectedMeterCalnumberisaccurate.
TestingtheFlowmeterCable
1.Disconnecttheconsolecontrolcablefromthe
owmetercable.
2.Holdthecablesothatthekeywayisinthe12o’
clockposition(Figure15).
G013306
1
2
3
4
Figure15
1.Keyway
3.Signal(6o’clockposition)
2.Ground(2o’clockposition)4.Power(10o’clockposition)
3.EnteraMeterCalnumber.RefertoEnteringthe
MeterCalNumberonpage8.
4.Pressthe[TotalVolume]key.
5.TurnthePump,Foot,andBoomswitchestotheOn
position.
6.Useasmalljumperwireorapapercliptocreatea
shortbetweenthe2o’clockand6o’clocksockets.
Note:Eachtimeyoumakecontact,theTotal
Volumeshouldincreaseby1ormorecounts.
7.IftheTotalVolumenumberdoesnotincrease,
replacethedefectivecable.
8.Performthevoltagechecks:2o’clockto6o’clock
(+5VDC);and2o’clockto10o’clock(+5VDC).
9.Ifallthecablesaregood,replacetheowsensor.
Note:Aftertestingtheowmetercables,enterthe
correctMeterCalnumberbeforespraying.
18