Note:Thepumpshouldincreasethepressureuntil
itreachesthedesiredrateifaSelfTestspeedhas
beenentered.
13.TurntheMasterBoomControl(foot)switchtothe
Offposition.
Note:Thesystemstopsthepump.
14.TurntheAgitationswitchtotheOnposition.
Note:Thesystemstartsthepumpandincreases
thepumpspeeduntilthepumpreachesthepreset
agitationpressure.Thesystemgoestothispressure
whentheboomsareoffandthepumpandagitation
areon.
15.TurntheAgitationswitch,andthePumpswitch
totheOffposition.
InitiallyField-testingthe
System
Beforeoperatingthespraysystem,performthis
procedure.
1.Drivethevehicleatthedesiredsprayingspeedwith
thesprayerboomsoff.
2.Pressthe[Speed]keytoverifythespeedreadout.
3.TurntheSpraypumpcontrolswitchtoRate1.
4.TurnthePowerswitchtotheOnposition.
5.TurntheFootswitchtotheOnposition.
Note:UsetheFootswitchwhenallthebooms
aretobeturnedon.
6.EnsurethattheBoom1,Boom2,andBoom3
switchesareintheOnposition.
7.SettheMan/RateswitchtoRate1.
8.Increaseordecreasethevehiclespeedby1mph
(2km/h).
Note:Thesystemshouldautomaticallycorrect
thetargetapplicationrate.Ifthesystemisnot
correctingtheapplicationrate,reviewtheInitial
SystemSetup;thenrefertoTroubleshooting.
9.Aftersprayingaswath,switchthefootswitchtothe
Offpositiontoshutoffthesprayowtoallbooms.
Note:Thisalsoshutsofftheacreagetotalizer.
10.Verifytheareacoveredandthevolumeofmaterial
sprayed.