39
Problem Corrective ActionPossible Causes
The Distance is inaccurate.
1. The speed sensor is not
calibrated correctly.
1. Calibrate the speed sensor.
2. The speed sensor is damaged. 2. Contact your Authorized
Service Dealer.
The monitor does not display
Aliti Rt
1. The monitor cable is loose. 1. Connect the monitor cable.
py
Application Rate.
2. The flowmeter is dirty or
clogged.
2. Clean the flowmeter.
3. The flowmeter is not calibrated
correctly.
3. Calibrate the flowmeter
4. The flowmeter is damaged. 4. Contact your Authorized
Service Dealer.
5. The speed sensor is not
calibrated correctly.
5. Calibrate the speed sensor.
6. The speed sensor is damaged. 6. Contact your Authorized
Service Dealer.
7. Nozzle size and vehicle speed
configuration is unable to reach
desired application rate.
7. Use the Nozzle Selection
Guide to choose the correct
configuration of nozzle and
vehicle speed.
The monitor displays 6553.5 when
in the Application Rate setting.
1. The monitor is not receiving
data from the speed sensor.
1. Contact your Authorized
Service Dealer.
The monitor is erratic in operation. 1. A two-way radio is too close to
the monitor or its cables.
1. Keep two-way radios away
from the monitor and its cables.
The displayed measurements do
not make sense.
1. The Units of Measurement is
set to a system other than what
you expect.
1. Check the Units of
Measurement to ensure that it
is set correctly.
The monitor reads “OFL.” 1. The data has exceeded the
maximum allowed.
1. Press and hold the [Reset]
button to clear the monitor.