Checkingthe
Leak-Detector-SystemOperation
1.MovetheignitionswitchtotheONposition.Do
notstarttheengine.
2.Removethehydraulic-tankbreatherfromthe
neckofthetank.
3.Insertacleanrodorscrewdriverintothetank
neckandgentlypushdownontheswitchoat
(Figure60);thealarmshouldsoundafterthe
1-seconddelay.
g228675
Figure60
1.Cleanrodorscrewdriver
3.Warningbuzzer
2.Pressdownonswitch
4.Releasetheoat;thealarmshouldstop
sounding.
5.Installthehydraulic-tankcap.
6.MovetheignitionswitchtotheOFFposition.
OperatingtheLeakDetector
Theleakdetectoralarmmaysoundfor1ofthe
followingreasons:
Aleakof118to177ml(4to6oz)hasoccurred.
Theuidlevelinthemainreservoirisreducedby
118to177ml(4to6oz)duetocontractionofthe
uidbycooling.
Ifthealarmsounds,turnoffthemachineasquicklyas
possibleandinspectitforleaks.Ifthealarmsounds
whileoperatingonagreen,driveoffthegreenrst.
Determinethesourceoftheleakandrepairitbefore
continuingoperation.
Ifyoudonotndaleakandsuspectafalsealarm,
movetheignitionswitchtotheOFFpositionandallow
themachinetostandfor1to2minutestoallowthe
uidlevelstostabilize.Thenstartthemachineand
operateitinanon-sensitiveareatoconrmthatno
leakexists.
Falsealarms,duetouidcontraction,maybecaused
byextendedidlingofthemachineafternormal
operation.Afalsealarmmayalsooccurifyouwork
themachineatareducedworkloadafteranextended
periodofaheavierworkload.T oavoidfalsealarms,
turnthemachineoffratherthanidlingforextended
periods.