Pass
Astheenginecooled,theresistancethroughthetemperaturesenderincreased.GotoStep4.
PlugconnectorP02intothetemperaturesender.
GotoStep4.
FailAstheenginecooled,theresistancethroughthetemperaturesenderdidnotincrease.Replace
thetemperaturesenderaccordingtotheprocedureoutlinedintheComponentT estingsectionin
Chapter6oftheGreensmasterTriFlex3320/3420ServiceManual.GotoReturningtheMachineto
Service(page21)andfollowthestepslisted.
Step4:Testthetemperaturesensorwiring.
ThisStepteststhetemperaturesenderwiringfromtheTEC-5001throughthetemperaturesender.
1.Removetherightsidecover(Figure62).
g237042
Figure62
1.Rightsidecover
2.Slidetheoperatorseatassemblyallthewaytowardtherearofthemachine.Thentilttheseatitselfforward.
3.LocatetheTEC-5001controller(Figure63).
98