Diagnostics
The Diagnostics function of the remote SmartHub allows for easy system troubleshooting. Within this function, the
user can monitor the SmartHub’s internal voltages as well as check the firmware version.
Use the Input Dial to navigate through the menus while in the Menu: field.
Menu: Link Monitor Allows user to monitor communication
network traffic.
Menu: Link Monitor
Naks: 000 Msg#: 000
FE: 000 Other:000
Menu: System Monitor Allows user to monitor all the SmartHubs in
the system.
Menu: Revision Displays the SmartHub firmware version and
creation date.
Scroll down to view the motherboard firmware
version as well.
Menu: Revision
Revision: 2.01p09
Rev Date: 10/9/19
GWY FL Ver 1.0 10/04/12
TM Hardware Ver: 1
Menu: PowerUp Detect Displays the number of detected stations,
number of detected sensors. It will also display
the date and time of the last power-down (PD)
and last power-up (PU). Press the Down arrow
to scroll down the informations.
Menu: PowerUp Detect
DC 2/500 DB[1,1,0,0]
PD 01/11/19 14:22:20
PU 01/12/19 09:57:24
I2C Events : 000 000
Reset Type : 09
Wire line found: No
Radio Anlg Enbl: No
Menu: Stations Alarms Displays any alarms generated by
communication failures between the TM and
any of its stations.
Menu: Station Last On Displays the time, date, current, and voltage of
the last activated station.
Menu: Sensor Monitor Displays real-time sensor information for all
enabled sensors.
Scroll down to review Rain Today, Rain
Yesterday, and Rain Window amounts.
Menu: Sensor Monitor
Hub Sensors
Inpt 1 Flow: 98.15gpm
Inpt 2 Rain: 00.20in
Inpt 3 Stat: CLOSED
Menu: VA Monitor Allows user to monitor the SmartHub’s
amperage, voltages and temperature
in real-time. This would be used when
troubleshooting the SmartHub’s internal circuit
voltages.
Menu: VA Monitor
Battery: 3.2V
LCD: 27C VL:-3.5V
34
Lynx® SmartHub Installation and User Guide