EasyManua.ls Logo

Toro Reelmaster 3555 - Hydraulic Fluid Capacity; Changing the Hydraulic Fluid

Toro Reelmaster 3555
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g341294
Figure91
1.Cap
3.Dipstick
2.Fillerneck(hydraulic-uid
reservoir)
3.Removethedipstickfromthellerneckand
wipeitwithacleanrag.
4.Insertthedipstickintothellerneck;then
removeitandchecktheuidlevel.
Note:Theuidlevelshouldbewithin6mm
(1/4inch)ofthemarkonthedipstick.
5.Ifthelevelislow,addthespecieduidtoraise
theleveltothefullmark;refertoHydraulicFluid
Specications(page59).
Important:Donotoverllthehydraulic
reservoir.
6.Installthedipstickandcapontothellerneck.
HydraulicFluidCapacity
22.7L(6USgallons);refertoHydraulicFluid
Specications(page59)
ChangingtheHydraulic
Fluid
ServiceInterval:Every2,000hours—Ifyou
areusingtherecommended
hydraulicuid,changethe
hydraulicuid.
Every800hours—Ifyouarenotusingthe
recommendedhydraulicuidorhaveever
lledthereservoirwithanalternativeuid,
changethehydraulicuid.
WARNING
Hothydraulicuidcancausesevereburns.
Allowthehydraulicuidtocoolbefore
performinganymaintenancetothehydraulic
system.
Iftheuidbecomescontaminated,contactyour
localTorodistributorbecausethesystemmustbe
ushed.Contaminateduidlooksmilkyorblackwhen
comparedtocleanoil.
1.Preparethemachineformaintenance;referto
PreparingforMaintenance(page41).
2.Disconnectthelargehydraulichose(Figure92)
fromthereservoir,andletthehydraulicuidow
intoadrainpan.
g020253
Figure92
1.Hydraulichose
3.Installthehydraulichosewhenhydraulicuid
stopsdraining.
4.Fillthereservoir(Figure93)withapproximately
22.7L(6USgallons)ofhydraulicuid;referto
HydraulicFluidSpecications(page59).
Important:Useonlythehydraulicuids
specied.Otheruidscouldcausesystem
damage.
g341294
Figure93
1.Cap
3.Dipstick
2.Fillerneck(hydraulic-uid
reservoir)
5.Installthedipstickandcapontothellerneck.