EasyManua.ls Logo

Toro Sand Pro 5040 - Hour Meter; Diode Assemblies

Toro Sand Pro 5040
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 5 – 10
Electrical System
Sand Pro & Infield Pro 3040/5040
Hour Meter
The hour meter used on the machine records the
amount of time that the ignition switch is in the ON posi-
tion.
Testing
1. Remove knob from lift lever.
2. Remove four (4) screws and flat washers that secure
control panel to console (Fig. 10). Lift control panel, un-
plug wire harness connector from hour meter and re-
move control panel from machine.
3. Connect the positive (+) terminal of a 12 VDC source
to the positive (+) terminal of the hour meter.
4. Connect the negative (–) terminal of the voltage
source to the other terminal of the hour meter.
5. The hour meter should move 1/10 of an hour in six
minutes.
6. Disconnect the voltage source from the hour meter.
7. Connect wire harness connector to hour meter and
position control panel to console. Secure control panel
with four (4) screws and flat washers (Fig. 10).
8. Install knob to lift lever.
1. Console
2. Lift lever knob
3. Control panel
4. Flat washer (4 used)
5. Screw (4 used)
6. Panel decal
7. Hour meter
Figure 10
6
7
2
3
4
1
5
Figure 11
QUARTZ
Hobbs
HOURS
1
0000
1
10
+
BACK
FRONT
Diode Assemblies
Diodes D1 and D2 provide logic for the interlock system.
The diodes plug into the wiring harness under the con-
sole control panel.
Testing
The diode (Fig. 12) can be tested using a digital multime-
ter (diode test or ohms setting) and the table below.
Multimeter
Red Lead (+)
on Terminal
Multimeter
Black Lead (–)
on Terminal
Continuity
Female Male YES
Male Female NO
Figure 12
1. Diode
2. Male terminal
3. Female terminal
1
2
3

Table of Contents

Other manuals for Toro Sand Pro 5040