ControlsSystem
Maintenance
AdjustingtheControls
Thefactoryadjuststhecontrolsbeforeshippingthe
machine.However,aftermanyhoursofuse,you
mayneedtoadjustthetractioncontrolalignment,
theNEUTRALpositionofthetractioncontrol,andthe
trackingofthetractioncontrolinthefullforward
position.
ContactyourAuthorizedServiceDealertoadjustthe
controlsofyourmachine.
HydraulicSystem
Maintenance
HydraulicSystemSafety
Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
HydraulicFluid
Specications
Hydraulic-TankCapacity:37.9L(10USgallons)
Useonly1ofthefollowinguidsinthehydraulic
system:
ToroPremiumTransmission/HydraulicTractor
Fluid(refertoyourAuthorizedServiceDealerfor
moreinformation)
ToroPremiumAllSeasonHydraulicFluid
(refertoyourAuthorizedServiceDealerformore
information)
IfeitheroftheaboveTorouidsarenotavailable,
youmayuseanotherUniversalTractor
HydraulicFluid(UTHF),buttheymustbeonly
conventional,petroleum-basedproducts.The
specicationsmustfallwithinthelistedrangefor
allthefollowingmaterialpropertiesandtheuid
shouldmeetthelistedindustrystandards.Check
withyourhydraulicuidsuppliertodetermineifthe
uidmeetsthesespecications.
Note:T orowillnotassumeresponsibilityfor
damagecausedbyimpropersubstitutions,souse
onlyproductsfromreputablemanufacturerswho
willstandbehindtheirrecommendations.
MaterialProperties
cStat40°C:55to62 Viscosity,ASTMD445
cStat100°C:9.1to9.8
Viscosityindex,ASTMD2270
140to152
PourPoint,ASTMD97-37to-43°C(-35to-46°F)