3.MAIN UNIT REPLACEMENT
EO18-33017
2.6 Replacing the Solenoid (Standard on the B-SX8T, Option for the B-SX6T)
2- 10
6. Remove the Head Cover Plate. (Refer to Section 2.5.)
7. Insert piled 10 pieces of tag paper of 8 inches or 6 inches (203.2 mm or 170.6 mm) in width, 0.16 mm in
thickness (I-BEST-S is recommended.) between the Print Head and the Platen. Then, turn the Head
Lever to the LOCK position.
8. Push and hold the Head Up Link against the Solenoid (c), and then press and fit the Solenoid Unit
snugly to the Head Up Link (d). Secure the Solenoid Unit with the screws.
9. Reassemble in the reverse order of removal.
CAUTION!
Orient the screws so that they are vertically aligned with the Solenoid Attachment Plate.
Push
Platen
Print Head
Push
Thickness: 1.6 mm
Head Up Link
Solenoid Unit