EasyManuals Logo

Toshiba e-BRIDGE Re-Rite User Manual

Toshiba e-BRIDGE Re-Rite
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Installation
14
SplitType
if Parameter contains
a valid value
(e.g. Page or
Barcode)
use SplitType
parameter in the
Group.cfg
the SplitType value
will be translated
into its Number
equivalent (for Page
= 1 and Barcode =
2)
ignored in Lookup
use SplitType
parameter in the
Group.cfg
the SplitType value
will be translated
into its Number
equivalent (for
Page = 1 and
Barcode = 2)
if Parameter is set to
None
use SplitType
parameter in the
Group.cfg
the SplitType value
will be translated
into its Number
equivalent (for None
= 0)
use SplitType
parameter in the
Group.cfg
the SplitType
value will be
translated into its
Number equivalent
(for Page = 1 and
Barcode = 2)
if Parameter is set to
Blank
(e.g. SplitType = )
use SplitType
parameter in
Global Settings
the SplitType value
in the Global settings
will be translated
into its Number
equivalent
use SplitType
parameter in
Global Settings
the SplitType value
in the Global
settings will be
translated into its
Number equivalent
if Parameter is not
existing
use SplitType
parameter in
Global Settings
the SplitType value
in the Global settings
will be translated
into its Number
equivalent
use SplitType
parameter in
Global Settings
the SplitType value
in the Global
settings will be
translated into its
Number equivalent
SplitAt
if Parameter contains
a value
(e.g. SplitAt =
123456)
use SplitAt
parameter in the
Group.cfg
ignored in Lookup
use SplitAt
parameter in the
Group.cfg
if Parameter is set to
Blank
(e.g. SplitAt = )
use SplitAt
parameter in Global
Settings
use SplitAt
parameter in Global
Settings
if Parameter is not
existing
use SplitAt
parameter in Global
Settings
use SplitAt
parameter in Global
Settings
OutputFileName
if Parameter contains
any of the default
FileName options
(e.g.
OutputFileName =
%f %w %d %t)
use Filename Format
in Group.cfg
use Filename Format in
Group.cfg
use Filename
Format in
Group.cfg
if Parameter contains
a custom value
(e.g.OutputFileName
= testfile)
use custom value for
the Filename Format
in Group.cfg
use custom value for
the Filename Format in
Group.cfg
use custom value
for the Filename
Format in
Group.cfg

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba e-BRIDGE Re-Rite and is the answer not in the manual?

Toshiba e-BRIDGE Re-Rite Specifications

General IconGeneral
BrandToshiba
Modele-BRIDGE Re-Rite
CategoryAll in One Printer
LanguageEnglish

Related product manuals