4.e-Filing-specific Adjustments
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC © 2018 TOSHIBA TEC CORPORATION All rights reserved
4-2
Procedures
Both the service technician and the user can perform all adjustments.
* This adjustment will have an effect only on images stored in the Auto Color mode.
(1) This adjustment is effective when you scan an original judged as a black image at the most
appropriate density level in the Auto Color modes.
Use steps (a) to (c) to adjust the density.
(a) Press [User Functions -User-] on [Home] screen to enter the “User Functions” menu.
(b) Press [Scan].
(c) Press [ ] or [ ] of the “B/W Adjustment for Standard” option to adjust the density level for
scanning the original judged as a black image in the Auto Color mode.
If the density level is set to “ ”, the original will be stored with the low density.
If the density level is set to “ ”, the original will be stored with the high density.
After adjusting the density, scan and store the original in the e-Filing box. Then check the image quality.
Only if the user’s desired image quality is still not obtained after the density has been adjusted, perform
the next procedure.
* This adjustment will have an effect only on images stored in the Auto Color mode.
(2) Select “High Quality” from among the “Image Quality for Black in ACS” options, to store the black-
and-white original in the Image smoothing mode.
Use steps (a) to (c) to select the “Image Quality for Black in ACS” option.
(a) Press [User Functions -User-] on [Home] screen to enter the “User Functions” menu.
(b) Press [Scan].
(c) Press [High Quality] in the “Image Quality for Black in ACS” option.
Caution after the adjustment
All scanning functions are implemented with reference to the density and the “Image Quality for Black in
ACS” option. They will affect the image quality of black-and-white originals stored in the Auto Color
mode. Therefore, carefully perform the adjustment, being aware that the image quality of all future
images will be changed, when storing originals other than the one that is used for the adjustment.
Remarks
If “High Quality” is selected from among the “Image Quality for Black in ACS” options and black-and-
white originals are scanned in the Auto Color mode and stored in the e-Filing box (Scan to Box), this
allows them to be stored in the Image Smoothing mode rather than in the binary mode, and eventually
provides better halftones. The data will increase in size, compared to those in the binary mode.
The adjustment of density will be effective, only if “Standard” is selected from among the “Image
Quality for Black in ACS” options.