1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC © 2018 TOSHIBA TEC CORPORATION All rights reserved
1-38
Procedure
Check that paper is not skewed in the side guides of the drawer in advance.
(1) Output a grid pattern of A3/LD size and check the tilted volume of an image (the value of “A-B”).
(2) Remove 5 screws and take off the left cover (Refer to “4.1.2. Left cover” in the Service Manual).
<Note>
Be sure to check the scale positions before carrying out
the adjustment. Take a memo of the scale positions
where the LSU holder [4] and the frame [5] ones are
aligned.
Fig. C: The scale position is aligned at the center. Fig. D:
The scale position is aligned at the fifth one on the front
side from the center.
(3) Loosen 2 screws [8].
(4) Remove 1 screw [9].