05/08 Mode Element
Item Subitem Code
Details
RAM Contents
t mode
quality
control
loop control
enforcement
When a service call has occurred or a warning
message (IQC/SPC) has appeared, "Image quality
control enforcement (05-2120)" should be performed
after the equipment is repaired or the cause of the error
is evaluated. In case the service call occurred or the
warning message (IQC/SPC) appeared again after the
performance of the code 05-2120, a test chart can be
printed out by temporarily using this code (05-2188) if
an image check is urgently needed.
t mode
sensor
2192 Humidity display 60 0-100 M
The humidity of the inside of the equipment is
displayed.[Unit: RH%]
t mode
sensor
2194 Temperature display 22 0-50 M
The temperature of the inside of the equipment is
displayed.[Unit: °C]
t mode
quality
control
temperature
A drum surface temperature detected at the drum
surface potential sensor control is displayed.
t mode
quality
control
display at image
quality closed-loop
control
A relative humidity detected at the image quality
closed-loop control is displayed.
t mode
quality
control
adjustment
contents
When the value increases, the laser power output
increases.
<Default value>
e-STUDIO556/656: 132
e-STUDIO756/856: 101
t mode
quality
control
adjustment
2250 1 2nd laser 101 0-255 M
When the value increases, the laser power output
increases.
Valid only for e-STUDIO756/856
t mode
for RADF copying
(color)
0: Same log table as the one used at copying with
original glass
1: Background reproduction - Light 2
2: Background reproduction - Light 1
3: Background reproduction - Dark 1
4: Background reproduction - Dark 2
t mode
adjustment
direction (scan.
When the value increases by "1", the image shifts by
approx. 0.0423 mm toward the front side of the paper.