e-STUDIO557/657/757/857
6
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
t mode
original
adjustment of lamp
lighting
Adjusts the starting time of lamp lighting when the
detection accuracy of dark originals is poor.
Maximum value: 255 (Minimum time + 2040 ms)
Minimum value: 0 (Minimum time)
t mode
adjustment of
scanning
When the value increases by "1", the trailing edge of
scanned original becomes longer by 0.3 mm at RADF
copying.
When the value decreases by "1", the trailing edge of
scanned original becomes shorter by 0.3 mm at RADF
copying.
* This code is effective when the value of 08-3075 is "1"
(Allowed).
t mode
polygonal motor
rotation speed
scanning direction
reproduction ratio
When the value increases in increments of "1", the
reproduction ratio of the primary scanning direction
increases as follows:
e-STUDIO557/657: 0.3 mm/step
e-STUDIO757/857: 0.1 mm/step
t mode
polygonal motor
rotation speed
scanning direction
reproduction ratio
When the value increases in increments of "1", the
reproduction ratio of the primary scanning direction
increases as follows:
e-STUDIO557/657: 0.3 mm/step
e-STUDIO757/857: 0.1 mm/step
t mode
writing start position
direction
When the value increases by "1", the writing start
position shifts to the front side by approx. 0.0423 mm.
t mode
writing start position
direction
contents
When the value increases by "1", the writing start
position shifts to the front side by approx. 0.0423 mm.
<Default value>
e-STUDIO557/657: 113
e-STUDIO757/857: 123
t mode
sideways deviation
4018 0 1st drawer 128 0-255 M
When the value increases by "1", the image shifts
toward the front side by 0.0423 mm.
t mode
sideways deviation
4018 1 2nd drawer 128 0-255 M
When the value increases by "1", the image shifts
toward the front side by 0.0423 mm.
t mode
sideways deviation
4018 2 3rd drawer 128 0-255 M
When the value increases by "1", the image shifts
toward the front side by 0.0423 mm.