e-STUDIO557/657/757/857
5
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
t mode
characteristic value
board
Transfers the characteristic values of the scanner
(shading correction factor / RGB color correction /
reproduction ratio color deviation correction / shading
position correction factor / reproduction ratio correction
value in primary scanning direction)
t mode
characteristic value of
scanner / SYS board
→ SLG board
Transfers the characteristic values of the scanner
(shading correction factor / RGB color correction /
reproduction ratio color deviation correction / shading
position correction factor / reproduction ratio correction
value in primary scanning direction) from the SRAM of
the SYS board to the SRAM of the SLG board.
t mode
sensor Auto adj.
Perform the adjustment and initialization when the
RADF board or RADF original reading start sensor is
replaced.
t mode
plate
Automatic dust
detection adjustment
plate
Automatic dust
detection adjustment
Performs adjustment for automatic dust detection with
the shading correction plate. If dust is detected,
shading correction is performed by avoiding the dust.
t mode
Scanner RADF EEPROM initialization 3220 EEPROM initialization - - - Initializes EEPROM for the RADF. 6
t mode
sensor Manual adj.
Adjusts the RADF original reading start sensor of the
RADF manually.
t mode
original
the primary scanning
direction
contents
Adjusts the detection range for size of original.
<Default value>
NAD/TWD/CND: 128
Others: 58
t mode
original
adjustment of
carriage
Adjusts the position where the carriage stops at the
size detection of the original.
Default value: 200 (20 mm from leading edge of
original)
Maximum value: 255 (25.5 mm from leading edge of
original)
Minimum value: 0 (0 mm from leading edge of original)
t mode
original
lighting time
Adjusts the lighting time of the lamp at the size
detection of the original.
Maximum value: 255 (Minimum time + 2040ms)
Minimum value: 0 (Minimum time)