e-STUDIO557/657/757/857
63
element
code
value
value
dure
e UI
Mode
waiting
temperature rising
period
(Normal temperature
environment)
contents
Sets for how many minutes the temperature is added
after warming-up in the low-temperature warming-up
control mode..
0: Not Added 1: 5 min. 2: 10 min. 3: 15 min. 4: 30
min. 5: 60 min. 6: 90 min. 7: 120 min. 8: 240 min. 9:
360 min. 10: 480 min. 11: Always Added
<Default value>
e-STUDIO557: 0
e-STUDIO657/757/857: 3
* The setting value of this code is applied when “1”
(enable) is set to the code 08-2226-0.
Mode
waiting
temperature rising
period
Low temperature
environment)
contents
Sets for how many minutes the temperature is added
after warming-up in the low-temperature warming-up
control mode.
0: Not Added 1: 5 min. 2: 10 min. 3: 15 min. 4: 30
min. 5: 60 min. 6: 90 min. 7: 120 min. 8: 240 min. 9:
360 min. 10: 480 min. 11: Always Added
<Default value>
e-STUDIO557: 0
e-STUDIO657/757/857: 3
* The setting value of this code is applied when “1”
(enable) is set to the code 08-2226-1.
Mode
waiting
temperature rising
period
(Normal temperature
environment)
contents
Sets for how many minutes the temperature is added
after warming-up in the low-temperature warming-up
control mode.
0: Not Added 1: 5 min. 2: 10 min. 3: 15 min. 4: 30
min. 5: 60 min. 6: 90 min. 7: 120 min. 8: 240 min. 9:
360 min. 10: 480 min. 11: Always Added
<Default value>
e-STUDIO557: 0
e-STUDIO657/757/857: 11
* The setting value of this code is applied when “1”
(enable) is set to the code 08-2226-2.