P9 ASD Installation and Operation Manual 189
Speed 1 Operation Time
Program Pattern Run Operation Time
This parameter sets the run-time for Preset Speed 1.
This time is effective when used with Group Speeds and non-Group Speeds.
If the Auto-Restart function is activated, the search time required for the Auto-
Restart function will be subtracted from the Operation Time setting; resulting
in a shorter run time.
Direct Access Number — F540
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000.0
Units — F520 Setting
Speed 2 Operation Time
Program Pattern Run Operation Time
This parameter sets the run-time for Preset Speed 2.
This time is effective when used with Group Speeds and non-Group Speeds.
If the Auto-Restart function is activated, the search time required for the Auto-
Restart function will be subtracted from the Operation Time setting; resulting
in a shorter run time.
Direct Access Number — F541
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000.0
Units — F520 Setting
Speed 3 Operation Time
Program Pattern Run Operation Time
This parameter sets the run-time for Preset Speed 3.
This time is effective when used with Group Speeds and non-Group Speeds.
If the Auto-Restart function is activated, the search time required for the Auto-
Restart function will be subtracted from the Operation Time setting; resulting
in a shorter run time.
Direct Access Number — F542
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000.0
Units — F520 Setting
Speed 4 Operation Time
Program Pattern Run Operation Time
This parameter sets the run-time for Preset Speed 4.
This time is effective when used with Group Speeds and non-Group Speeds.
If the Auto-Restart function is activated, the search time required for the Auto-
Restart function will be subtracted from the Operation Time setting; resulting
in a shorter run time.
Direct Access Number — F543
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000.0
Units — F520 Setting
Speed 5 Operation Time
Program Pattern Run Operation Time
This parameter sets the run-time for Preset Speed 5.
This time is effective when used with Group Speeds and non-Group Speeds.
If the Auto-Restart function is activated, the search time required for the Auto-
Restart function will be subtracted from the Operation Time setting; resulting
in a shorter run time.
Direct Access Number — F544
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000.0
Units — F520 Setting
Speed 6 Operation Time
Program Pattern Run Operation Time
This parameter sets the run-time for Preset Speed 6.
This time is effective when used with Group Speeds and non-Group Speeds.
If the Auto-Restart function is activated, the search time required for the Auto-
Restart function will be subtracted from the Operation Time setting; resulting
in a shorter run time.
Direct Access Number — F545
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000.0
Units — F520 Setting
F540 F545