P9 ASD Installation and Operation Manual 255
Table 12. My Function Operator Selections.
My Function Computational Selections
Input
Function
Command
Function Name Function Description
0 NOP (No Operation) Disables the My Function feature.
1 ST Execute data read/transfer.
2 STN Execute inverted data read/transfer.
3 AND Logical product of A AND B.
4 ANDN Logical product of A AND B
.
5 OR Logical sum of A OR B.
6 ORN Logical sum of A OR B
.
7 EQ Compares data — Outputs 1 if Equal; 0 if not Equal.
8 NE Compares data — Outputs 0 if Equal; 1 if not Equal.
9 GT Compares data — Outputs 1 if A>B; 0 if AB.
10 GE Compares data — Outputs 1 if AB; 0 if AB.
11 LT Compares data — Outputs 1 if AB; 0 if AB.
12 LE Compares data — Outputs 1 if AB; 0 if A>B.
13 ASUB Outputs absolute difference between A and B — |A–B|
14 ON (Timer)
Enables the On response time delay settings of My Function Time Data 15
(F928 F932) for My Function Data.
15 OFF (Timer)
Enables the Off response time delay settings of My Function Time Data 15
(F928F932) for My Function Data.
16 COUNT1 (Timer) Outputs a 1 upon reaching the pulse count setting of F933.
17 COUNT2 (Timer) Outputs a 1 upon reaching the pulse count setting of F934.
18 HOLD Outputs the peak output value since powering up or since the last reset.
19 SET Sets data.
20 RESET Resets data.