EasyManua.ls Logo

Toshiba Q9+ - Page 92

Toshiba Q9+
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80 https://www.toshiba.com/tic/
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
Manual Torque Boost 1
Program Fundamental Motor Set 1
The Manual Torque Boost 1 function is used to increase the low
frequency torque for high-inertia loads by increasing the output
voltage at frequencies below ½ of the Base Frequency 1 (F014)
setting.
The value programmed as a boost percentage establishes an
output voltage vs. output frequency relationship to be used to
start the motor or to provide smoother operation.
Note: Setting an excessive Torque Boost level may cause
nuisance tripping and mechanical stress to loads.
Direct Access Number
F016
Parameter Type — Numerical
Factory Default — (ASD-Depen-
dent)
Changeable During Run — Yes
Minimum — 0.0
Maximum — 30.0
Units — %
Motor Overload Protection Configuration
Program Protection Overload
This parameter is used to enable the Soft Stall feature which pro-
tects the motor from an over-current condition by reducing the
output frequency during a temporary increased current require-
ment from the load.
A V/f motor may be specified here along with the Overload Stall
to better match the ASD to the application.
This parameter setting may extend the Over-Voltage Stall time
settings.
Settings:
0 — Motor Overload Trip without Soft Stall
1 — Motor Overload Trip with Soft Stall
2 — Without Motor Overload Trip or Soft Stall
3 — Soft Stall Only
4 — V/f Motor Overload Trip without Soft Stall
5 — V/f Motor Overload Trip with Soft Stall
6 — V/f Motor without Overload Trip or Soft Stall
7 — V/f Motor Soft Stall Only
Direct Access Number
F017
Parameter Type — Selection List
Factory Default — Motor Over-
load Trip with Soft Stall
Changeable During Run — Yes
F016F018

Table of Contents

Related product manuals