EasyManua.ls Logo

Toshiba RAS-107SAV-E3 - Refrigerant Cycle Diagram; Refrigerant Flow and Components

Toshiba RAS-107SAV-E3
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
7. REFRIGERANT CYCLE DIAGRAM
7-1. Refrigerant Cycle Diagram
NOTE :
The maximum pipe length of this air conditioner is 10 m. The addition charging of refrigevant is
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
INDOOR UNIT
T1
TO
Temp. measurement
TC
TA
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Allowable height
difference : 10m
Allowable pipe length
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
TD
4-way valve
(STF-0108Z)
Compressor
DA89X1C-23EZ
T2
Outdoor heat
exchanger
Temp. measurement
Propeller fan
Refrigerant amount : 0.63kg
OUTDOOR UNIT
Muffler
Muffler
Ø1.0 x 600
TE
Ø1.0 x 600
Min. : 2m
Chargeless : 10m
Max. : 10m
unnecessary because this air condition is design with charge-less specitication.