RemarksProcedure
1) Remove the back cabinet and side cabinet.
(7 screws)
1) Perform the process • above.
2) Remove the fixing screw securing the capacitor
band.
(1- ST2T ø4 x 8 )
3) Remove the cable connected to the terminal.
1) Perform the process • above.
2) Remove the fixing screw.
(1- ST2T ø4 x 8 )
3) Remove the cable connected to the terminal.
1) Perform the process • above.
2) Remove Fastons of leads.
3) Remove the fixing screw.
(1- ST2T ø4 x 10 )
4) Pull OL holder up and remove Overload relay from
OL holder.
1) Perform the process • above.
2) Remove terminal cover of compressor.
3) Remove thermo holder and pull thermostat bimetal
up.
4) Remove Fastons of leads.
No.
‚-1
‚-2
‚-3
‚-4
‚-5
Part name
Back cabinet
Side cabinet
Capacitor for
compressor
Capacitor for fan
motor
Overload relay
Thermostat
bimetal