CIX40 Installation
CIX40 Installation
Installing the CIX40 Cabinet
Strata CIX40 Installation & Maintenance 5/06 1-31
Figure 1-23 HPFB-6 Reserve Power Installation
Step 10: Install Wiring
1. Refer to Figure 1-24 for the following steps. Loosen the screw on the Amphenol clamp and
remove the clamp. Plug in the 25-pair Amphenol connector and replace the clamp to hold the
Amphenol connector in place.
2. Connect all other PCB wiring (e.g., modular CO line cords, LAN cable, etc.). Slide the shorter
tie-wrap through the holder. Then fasten wiring to the unit with the tie wrap that comes with the
cabinet.
3. Connect the end of the AC adapter cable to the GMAS PCB as shown in Figures 1-24 and 1-7.
4. Connect the other end of the GCTU2 (100Base TX) LAN cable to the LAN connected to a LAN
switch or the eManager PC.
5. Plug the AC adapter into a power outlet.
6. Put the On/Standby switch on the GMAU2 into the “On” position. The DC LED should light
green. The CIX40 is now ready to program.
CAUTION! Do not wrap the power cord around the AC adaptor. Excess cord should be
gathered and secured with the supplied strap as shown in Figure 1-7. The cord
bundle may be secured to the side of the adapter.
WARNING! Do not smoke near batteries. Avoid creating any electrical sparks near
batteries.
2“
From Second HPFB (optional)
To P10 Connector (see Fig. 1-2)
HPFB Unit:
Reserve Power Battery
and Charger (optional)
#10 AWG HPFB
FG Wire to TB1
(see Fig. 1-2)
7253
2“
2“
2“