CIX40 Installation
CIX40 Installation
Loop Limits
Strata CIX40 Installation & Maintenance 5/06 1-33
Loop Limits
This section provides the maximum loop lengths for connection of telephones, lines, peripheral
equipment, and power supplies. The following information applies to only the Strata CIX40 system
(see Table 1-14).
Table 1-14 Digital Telephone/DIU/DDSS Console/ADM/Loop Limits
Mode
CIX40 Cabinet
or
Battery Backup
1
1. Battery backup applies to instances when the system is being powered by batteries exclusively.
Maximum line length (24 AWG)
1 Pair
feet meters
1 Pair plus
external power
2
2. Digital cable runs must not have the following:
Cable splits (single or double)
Cable bridges (of any length)
High resistance or faulty cable splices
DKT3000, DKT3200-series or
DKT2000-series models, DKT with
BVSU
3
or DVSU or BHEU or HHEU.
3. CIX40 does not support Speaker OCA.
CIX40 Cabinet 1000 303
1000 feet
(303 meters)
Battery Backup 695 204
DKT with BPCI
CIX40 Cabinet 1000 303
Battery Backup 500 151
DKT with BPCI and BHEU
CIX40 Cabinet 1000 303
Battery Backup 500 151
DDSS3060 or 2060
CIX40 Cabinet 1000 303
Battery Backup 675 204
DDCB3A
CIX40 Cabinet 165 50
Battery Backup 500 151
BATI, RATI
CIX40 Cabinet 1000 303
Battery Backup 1000 303
DKT with 1 ADM
CIX40 Cabinet 675 204
Battery Backup 165 50
DKT with 2 ADMs
CIX40 Cabinet 500 151
Battery Backup 33 10