- 12 - tousek / E_PULL-T24-T24speed_49002410 / 06. 08. 2019
Main layer Sub layer Settings/adjustments
button/switches
page 13
impulse button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEAD MAN
*) if impulse button is
set to DEADMAN, then
the pedestrian and
close button are also
set automatically to
DEADMAN mode.
(not selectable under
„pedest.- button“)
)
pedestrian button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
Impulse OPEN
DEAD MAN
*)
safety
page 15
G
photocell
active
not active
G
main safety edge
active
radio edge TX
TX 400
not active
G
side safety edge
active
radio edge TX
TX 400
not active
photoc.-function
when closing reverse
stop - after release open
during close stop, then close
PHC-pause time
no inuence of photocell
abort of pause time
re-start of pause time
immediate close after opening
PHC-self test
active
not active
motor
page 19
max. force
50...100% [increment 5 ] = 100%
ARS-response time
0,15...0,95s [increment 0,05] = 0,50s
speed
55...100% [increment 5] = 100%
soft stop way
0...2m [increment 0,1] = 0,5m
soft speed
10...50% [increment 5] = 40%
limit position OPEN
0...-30 [increment 1] = -5
limit position CLOSE
0...-30 [increment 1] = -5
operating mode
page 20
impulse mode
stop, start of pause time
impulse suppression when opening
pause time extension
G
opening direction
<<<
–
left
–
>>> right
G
operating mode
impulse mode
aut. close 1...255s [increment 1]
partial opening
10...100% [increment 1] = 30%
automatic mode
complete/partial opening
only complete opening
only partial opening
pause time logic
no inuence
always open in automatic mode
lights/lamps
page 21
prewarning OPEN
OFF, 1...30s = OFF
prewarning CLOSE
OFF, 1...30s = OFF
additional module
yard/control light
status display 1
status display 2
courtyard light
1)
OFF, 5...950s =
OFF
control lamp
1)
illuminates when opening/closing
blinks slowly / illuminates / blinks
illuminates in open position
diagnosis
page 23
status display
status display of all inputs
delete position
NO
YES
factory setting
NO
YES
software version
show software version
serial number
show serial number
protocol
show protocol notes
status sensor
show sensor
1)
The menu points courtyard lamp and control lamp will only appear on display if in menu
„Additional module" courtyard lamp/control lamp is selected.
Menu structure Adjustments - overview
+
–
integr. control board for sliders PULL
T24, -T24speed
ESC
ENTER
Note: some adjustments regarding function or operating logic can only be executed if gate is closed and if the display shows „ready“.