EasyManua.ls Logo

Trane RTAF-SVX001K-EN - Compressor Model Number; Compressor Serial Number

Trane RTAF-SVX001K-EN
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model Number Descriptions
8 RTAF-SVX001K-EN
Digit 35 — Smart Flow Control
X= None
Digit 36 — Structural Options
A = Standard Unit Structure
D = Wind Load for Florida Hurricane
Digit 37 — Appearance Options
X = No Appearance Options
A = Architectural Louvered Panels
Digit 38 — Unit Isolation
X= None
1 = Elastomeric Isolators
Digit 39 — Shipping Package
X = No Shipping Package
A = Containerization Package
T = Shipped with Tarp Covering
Full Unit
Digits 40, 41
XX = Reserved for future use
Digit 42 — Free-Cooling
X= None
F = Total Free-Cooling — Glycol
Digit 43 — Special Requirement
0= None
F = Ship to Final Finisher
S = Special Requirement
Compressor Model
Number
Digits 1-3 — Compressor Family
CHH= Positive displacement,
refrigerant, helical rotary,
hermetic compressor
Digit 4 — Compressor Type
P = GP2, available on some smaller
RTAF chillers
T= GP2+
W= GP2.5
Digit 5 — Economizer Port Detail
0 = No Economizer Port
A = Economizer Port = 65°, Vi = 3.5
E = Economizer Port = 140°, Vi = 3.57
Digit 6 — Frame Size
L = L Frame
M = M Frame
N = N Frame
Digit 7 — Compressor Capacity
1 = GP2 Smaller Capacity (minor)
2 = GP2 Larger Capacity (major)
3 = GP2+ Smaller capacity (minor)
4 = GP2+ Larger capacity (major)
5 = GP2.5 Smaller capacity (minor)
6 = GP2.5 Larger capacity (major)
Digit 8 — Motor Voltage
D = 380-60-3
H = 575-60-3
T = 400/460-50/60-3
used for 380-50-3
K = 460-60-3 (N6 only)
Digit 9 — Internal Relief
K = 450 psid
Digits 10-11 — Design Sequence
** = Factory assigned
Digit 12 — Capacity Limit
N = Standard capacity
Digits 13-15 — Motor kW Rating
048 = L1 50Hz
057 = L1 60Hz
058 = L2 50Hz
069 = L2 60Hz
065 = M3 50Hz
077 = M3 60Hz
077 = M4 50Hz
092 = M4 60Hz
093 = N3/N5 50Hz
112 = N3/N5 60Hz
112 = N6 50Hz
134 = N6 60Hz
Digit 16 — Volume Ratio
A = High Volume Ratio
Compressor Serial
Number
Digits 1-2 — Year
YY = Last two digits of year of
manufacture
Digits 3-4 — Week
WW= Week of build, from 00 to 52
Digit 5 — Day
1= Monday
2 = Tuesday
3 = Wednesday
4 = Thursday
5 = Friday
6= Saturday
7 = sunday
Digits 6-8 — Coded Time Stamp
TTT= Used to ensure uniqueness of
serial number
Digit 9 — Assembly Line
L = Varies with facility
Digit 10 — Build Location
A= Monterrey

Table of Contents