AP4119 Rail Tag Programmer User Guide
TransCore Proprietary
3–20
All programmer commands are in the following format:
where
#abcxxxxxx...xxxxxx<cr>
# start of command character. All commands must start with this character.
abc the command
xxx... user data
<cr> carriage return
If command execution is successful, the programmer sends the response
#Done<cr>
If command execution is unsuccessful, the programmer sends the response
#Error<cr>
Serial Command Set
Programmer commands are listed below. Use these commands by following the format described in the
“Command Execution Protocol” section above.
Note: The tag may be placed into the tag holder before issuing the command, or with the tag
holder door open, enter the command and place the tag into the tag holder within 10 seconds. If the
tag is not placed in the tag holder and the door is not closed within 10 seconds,the programmer will
abort this command. See “Programming a Tag” on page 3–25 for tag insertion instructions.
#120<cr> Enable Tone Generator
The default state of the audible tone generator is tone-enabled. The tone generator creates audible
responses described as a beep, triple beep, and solid tone. This command re-enables the programmer’s
audible response capability after it has been disabled by the #121 command.
Response:
#Done<cr>
#121<cr> Disable Tone Generator
This command disables the programmer’s audible response capability. The default state of the audible
tone generator is tone-enabled.
Response:
#Done<cr>