Chapter 3 Operating the Programmer
TransCore Proprietary
3–23
Response:
#xx<cr>
#Done<cr>
or
#Error<cr>
#230yy<cr> Read a Page of Data Using Hex Format
The programmer reads hex data (xxxxxxxxxxxxxxxx), 16 hex characters, starting at hex address yy.
The starting address (yy) must be on an 8-byte page boundary. For example, the starting address will be
00, 08, 10, 18, …
If the tag is not already in the tag holder, a series of beeps indicates that the programmer is waiting for a
tag to be placed in the holder. If the tag is not placed in the tag holder and the door is not closed within 10
seconds, the programmer will abort this command. See “Programming a Tag” for tag insertion instructions.
The programmer will not read the data if the programmer does not have permission to read the memory
area of the tag that is requested by the user. Each programmer will be assigned permissions at the
factory, or through the use of a permissions tag that must be placed in to the programmer at pre-specified
intervals.
Response:
#xxxxxxxxxxxxxxxx<cr>
#Done<cr>
or
#Error<cr>
#231yy<cr> Read a Byte of Data Using Hex Format
The programmer reads a byte of hex data (xx), 2 hex characters, from hex address yy. If the tag is not
already in the tag holder, a series of beeps indicates that the programmer is waiting for a tag to be placed
in the holder. If the tag is not placed in the tag holder and the door is not closed within 10 seconds, the
programmer will abort this command. See “Programming a Tag” for tag insertion instructions.
The programmer will not read the data if the programmer does not have permission to read the memory
area of the tag that is requested by the user. Each programmer will be assigned permissions at the
factory or through the use of a permissions tag that must be placed in to the programmer at pre-specified
intervals.
Response:
#xx<cr> #Done<cr>
or
#Error<cr>
#30<cr> System Reset
The command resets the programmer to its original power-on state with the self-test. System reset takes
approximately three seconds.