2. Web Configuration Interface
2.4.7 User Targets
By default, administrators are allowed access to all servers. However, you must define the access rights of each user account to the
following:
• Target Access – To initiate a remote session for the corresponding port.
• Virtual media access – To use the Virtual Media functionality when in a remote session for the corresponding port.
To configure User Targets:
1. From the Configuration section, select the User Targets tab. The User Targets page appears.
2. From the User dropdown menu, select an account to configure.
3. In the Target Access column, check the checkboxes of all ports that you are giving the account permission to access.
Note: You can click on the Unselect all Target Access button at the top of the column to clear the checkboxes of all ports. Correspondingly, you can
check the Select all Target Access button at the top of the column to check the checkboxes of all ports.
4. In the Virtual Media Access column, check the checkboxes of all ports that you are giving the account Virtual Media permission for.
Note: You can click on the Unselect all Virtual Media Access button at the top of the column to clear the checkboxes of all ports. Correspondingly, you
can check the Select all Virtual Media Access button at the top of the column to check the checkboxes of all ports.
5. Click the Save button at the top of the screen to save your changes.
2.4.8 Power Devices
The Power Devices section allows for IP PDUs to be added to the KVM switch. Via the Power Outlets section (See section 2.4.9 Power
Outlets for details), the NetCommander IP KVM ports can then be mapped to a port on one of these, allowing you to Power Cycle a port or
turn its power Off/On.
To Add a PDU:
1. From the Configuration section, select the Power Devices tab. The Power Devices page appears.
2. Click the Add button. The Add PDU page opens.

Other manuals for Tripp Lite NetCommander B070-016-19-IP2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tripp Lite NetCommander B070-016-19-IP2 and is the answer not in the manual?

Tripp Lite NetCommander B070-016-19-IP2 Specifications

General IconGeneral
Display diagonal19 \
Display resolution1280 x 1024 pixels
On Screen Display (OSD)Yes
Product colorBlack
Country of originTaiwan
Security algorithms128-bit AES, 802.1x RADIUS, HTTPS
Height (in Rack Units)1
KVM switch ports quantity16
Operating temperature (T-T)-4 - 140 °F
Sustainability certificatesRoHS
CertificationUL 60950-1 (USA), CAN/CSA (Canada), FCC Part 15 Class A, CE, IEC 60950-1
Input current1.2/0.7 A
AC adapter frequency50/60 Hz
AC adapter input voltage100 - 240 V
InterfacePS/2; USB; VGA
Storage temperature (T-T)-20 - 60 °C
Package depth891.5 mm
Package width591.8 mm
Package height149.9 mm
Package weight19780 g
Master (outer) case width595.1 mm
Master (outer) case height150.1 mm
Master (outer) case length833.9 mm
Master (outer) case weight17960 g
Quantity per master (outer) case1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Depth692.4 mm
Width477.3 mm
Height43.4 mm
Weight12910 g