Start a welding arc, if there is a pulse
on the current channel the values will
be shown here.
Press OSCILOSCOPE
The AMV now displays the welding
waveform
To look at the waveform while
recording, press PAUSE,
then use the graph tools to zoom in
Press DIGITAL to return to the digital
screen
Here you can see the display has been
zoomed in to show 1 wavefrom.
Press DIGITAL to return to the digital
screen.
Stop the welding arc
To do a PASS COMPLETE press